Every mof file failed "An error occurred while opening the namespace for object 1 defined on lines xx - xx: Error Number: 0x8007007e, Facility: Win32 Description: The specified module could not Monday, July 12, 2010 10:13 PM Reply | Quote 0 Sign in to vote dude nice...fixed it...crazy...later bro Friday, December 10, 2010 1:32 AM Reply | Quote 0 Sign in to Running the printer install script manually, an error message was returned. It recompiles all .mof WMI files found in the %windir%\System32\Wbem\Repository folder. have a peek here

If you own the SonicWALL product requested please confirm that you have registered your product at My SonicWALL . Inside of a dog, it's too dark to read. Background: system is a home Thinkpad T500 Win 7 Ultimate, no problems for ~2 years,clean per Norton and Malware, windiag 2.1 indicates same issue, unable to connect to root. Wait for the Last Seen/Last Tried date listed in the Summary tab of the computer webpage to update, indicating that a new scan attempt has taken place.

It gave a line number in the script and an error message of "The specified module could not be found". Typefor /f %s in ('dir /b *.dll') do regsvr32 /s %sand press Enter to re-register WMI DLL files. 5. Note:The Windows Management Instrumentation service starts automatically when you restart the computer. NewTreeWmi.cpp(17)[2012-06-27 00:04:02] [ERROR] Exception catched in file .\NewTreeRootWorker.cpp, function NewTreeRoot::Worker::FillAudio, line 215[2012-06-27 00:04:02] [ERROR] The specified module could not be found.

  1. I downloaded and installed Speccy again and nothing changed.Any help will be greatly appreciated.
  2. TechNet Products IT Resources Downloads Training Support Products Windows Windows Server System Center Browser   Office Office 365 Exchange Server   SQL Server SharePoint Products Skype for Business See all products
  3. OK. .1568 14:55:57 (2) !!
  4. Tuesday, September 29, 2009 7:49 AM Reply | Quote 18 Sign in to vote You may try this: Copy the file: "framedyn.dll" from folder: "C:\WINDOWS\system32\wbem" TO folder: "C:\WINDOWS\system32" .
  5. Or just manually done the above mentioned service/folder pairing? 0 Thai Pepper OP Eric M Feb 26, 2016 at 7:55 UTC If it's just one machine, it sounds
  6. I've always found Speccy to be a helpful tool.Thanks,Richard William Posner Back to top #2 OFFLINE nodles nodles Power Member Beta Testers 1,364 posts Gender:Male Location:Finland Posted 23 June 2012 -

Type for /f %s in (‘dir /b *.dll') do regsvr32 /s %s and press Enter to re-register WMI DLL files. 5. Please re-enable javascript to access full functionality. About Advertising Privacy Terms Help Sitemap × Join millions of IT pros like you Log in to Spiceworks Reset community password Agree to Terms of Service Connect with Or Sign up OK. .1585 14:55:57 (0) ** WMI providers EXE/DLL availability: .................................................................................

it maybe works~ Marked as answer by Nick-Williams Tuesday, October 13, 2009 9:37 AM Tuesday, October 13, 2009 9:35 AM Reply | Quote 0 Sign in to vote You are my Right-clickCommand Promptand selectRun as Administrator. 3. DISABLED. .1588 14:55:57 (0) ** INFO: Local Account Filtering: ...................................................................................... I did attempt to recompile the mof file, but as stated originally the file itself did not initially exist so I copied it from another installation and recompiled successfully but that

DISABLED. .1542 14:55:57 (0) ** => This will prevent any WMI inbound connectivity to this machine. .1543 14:55:57 (0) ** Note: The rule 'Windows Management Instrumentation (WMI-In)' rule must be ENABLED Could this be my problem? 0 Text Quote Post |Replace Attachment Add link Text to display: Where should this link go? In the right pane of the Service console, locate and right-click Windows Management Instrumentation, and then select Stop to stop the service. 3. Typefor /f %s in ('dir /b *.dll') do regsvr32 /s %sand press Enter to re-register WMI DLL files. 5.

RSOP.msc wont even open. Microsoft Customer Support Microsoft Community Forums Resources for IT Professionals   Sign in United States (English) Brasil (Português)Česká republika (Čeština)Deutschland (Deutsch)España (Español)France (Français)Indonesia (Bahasa)Italia (Italiano)România (Română)Türkiye (Türkçe)Россия (Русский)ישראל (עברית)المملكة العربية السعودية (العربية)ไทย All rights reserved. it maybe works~ Marked as answer by Nick-Williams Tuesday, October 13, 2009 9:37 AM Tuesday, October 13, 2009 9:35 AM Reply | Quote All replies 0 Sign in to vote Hi,If

Here are the detailed steps: 1. navigate here ENABLED. .1517 14:55:57 (0) ** => This will prevent any WMI remote connectivity to this computer except .1518 14:55:57 (0) ** if the following three inbound rules are ENABLED and non-BLOCKING: After that, type the command wmiprvse /regserver and press Enter. 7. If you need immediate assistance please contact technical support.

Note:The Windows Management Instrumentation service starts automatically when you restart the computer. ERROR: WMI CONNECTION errors occured for the following namespaces: .................................................. 16 ERROR(S)! .1603 14:55:57 (0) ** - Root, 0x8007007E - The specified module could not be found.. .1604 14:55:57 (0) ** After completed, type for /f %s in (‘dir /b *.mof') do mofcomp %s and press Enter to re-compile WMI mof files. 6. http://chatflow.net/windows-7/windows-update-high-cpu-windows-7.html Ive got the computer imaged and hosted on our HyperV server..

Continue × Register as SonicWALL User Sorry, we are having issues processing your request. NewTreeWmi.cpp(17)[2012-06-27 00:04:05] [ERROR] Exception catched in file .\NewTreeRootWorker.cpp, function NewTreeRoot::Worker::FillGraphics, line 250Paulemail link removed by moderator to avoid spamming Back to top #4 OFFLINE Alan_B Alan_B Super Hero Members 4,295 posts https://www.microsoft.com/en-us/download/details.aspx?id=7684Have you attempted to use the winmgmt.exe command line utility to rebuild the repositories automagically?

The first technician to respond also noted that when looking at the Computer properties, it would return ‘not available' for the "Processor:" and "Installed memory (RAM):" fields.

I have uninstalled Speccy twice and downloaded it from the two different sites hoping it may have been corrupted but to no avail. Start the Windows Management Instrumentation service and change the Startup Type back to Automatic. Please guide me. OK × Welcome to Support You can find online support help for*product* on an affiliate support site.

However, if the WMI service is stopped, .1562 14:55:57 (0) ** this can prevent the service/application to work as expected. .1563 14:55:57 (0) ** .1564 14:55:57 (0) ** RPCSS service: ...................................................................................................... Thanks lzw430074!!! Wang! this contact form PrintInfo.cpp(132)[2012-06-27 00:04:02] [ERROR] Exception catched in file .\PrintInfo.cpp, function CPrinterInfo::SetFormats, line 166[2012-06-27 00:04:02] [ERROR] The specified module could not be found.

Back to top #3 OFFLINE PRStephens PRStephens Newbie Members 4 posts Posted 27 June 2012 - 01:33 AM I am running Win7 64 bit with an Intel i5 quad core processor. Reply Subscribe 11 Replies Jalapeno OP tech-brad Feb 26, 2016 at 7:21 UTC Dang, maybe just re-image it at this point. Full error message is as follows: Cannot connect to WMI provider.  You do not have permission or the server is unreachable.  Note that you can only manage SQL Server 2005 and ERROR: WMI MONIKER CONNECTION errors occured for the following namespaces: .......................................... 1 ERROR(S)! .1600 14:55:57 (0) ** - Root, 0x8007007E - The specified module could not be found.. .1601 14:55:57 (0)

ERROR: WMI CONNECTION errors occured for the following namespaces: .................................................. 16 ERROR(S)! .2014 14:30:54 (0) ** - Root, 0x8007007E - The specified module could not be found.. .2015 14:30:54 (0) ** Tuesday, October 13, 2009 9:36 AM Reply | Quote 0 Sign in to vote Stilltroubled byit? It is working for me. Disable and stop the Windows Management Instrumentation service. 2.

NewTreeWmi.cpp(17)[2012-06-27 00:04:02] [ERROR] Exception catched in file .\NewTreeRootWorker.cpp, function NewTreeRoot::Worker::FillHd, line 235[2012-06-27 00:04:02] [ERROR] The specified module could not be found. Right-clickCommand Promptand selectRun as Administrator. 3. Where do I go from here?here is the log file [2012-06-27 00:04:02] [ERROR] The specified module could not be found. Kitts & Nevis St.

Hi, Please perform the following steps to troubleshoot the issue: 1.Log onto Windows 7 with an administrator account, clickStart, typeservices.mscin the Start Search box and press Enter. 2.In the right pane Disable and stop the Windows Management Instrumentation service. 2. service was not running until after Speccy tried to access its information,and by the time it was running and the information was available Speccy had given up waiting. ive been to every technet article, blog, etc and I cannot seem to get this fixed.

Start Windows Explorer, and then locate the %SystemRoot%System32WbemRepository folder. 4. I guess the software needs something I don't have or don't allow on my system but it is not because of the WMI.What other dependancies does Speccy have?respectfully,Paul Back to top I received what I like to call a "pile of symptoms" and get to try to find the root cause. The files that were deletedwill bere-created when the computer restarts.

The files that were deletedwill bere-created when the computer restarts. Wednesday, December 23, 2009 2:34 AM Reply | Quote 1 Sign in to vote Also...check your environment variables...the PATH variable, and make sure that systemroot...system32 and systemroot ...system32\wbem are there and Creating your account only takes a few minutes.