Home > The Specified > The Specified Image File Is Either Invalid Or Corrupt

The Specified Image File Is Either Invalid Or Corrupt

Anyone experience this or know what the problem is? >> >> Thanks >> >> "Humphrey" wrote: >> >> > On Mar 21, 7:46 am, tedkar wrote: >> > > I This occurs if the linker can not match an input section to any of the selectors in your scatter file. This attribute is applicable to execution regions only. I am having a problem adding the INSTALL.WIM from the Vista DVD so I can utilize an unnattended install. Check This Out

See the following in the Linker Reference:RENAME.L6281E Cannot rename both and to . Privacy statement  © 2016 Microsoft. I am having a > problem adding the INSTALL.WIM from the Vista DVD so I can utilize an > unnattended install. For example, change: STMFD sp!, {r0-r3, lr} ; push an odd number of registers to STMFD sp!, {r0-r3, r12, lr} ; push even number of registers The assembler automatically marks the

See the following in the Linker Reference:--cpu=name.L6464E Only one of --dynamic_debug, --emit-relocs and --emit-debug-overlay-relocs can be selected. In other cases, please make sure you have the latest patch installed from: http://www.arm.com/support/downloads.For more information see Value out of range for relocation.L6287E Illegal alignment constraint () specified for (). L6725W Unused virtual function elimination might not work correctly, because there are dynamic relocations. The ISO was created using the Media Creator Tool.

  1. Auch hier erschien eine Fehlermeldung: Die angegebene Abbilddatei ist ungültig oder beschädig bzw.
  2. i tried another disk of windows 8.
  3. The error message I receive when I try to add it is > > "The specified image file is either invalid or corrupt." I tried several > > DVD's but had
  4. I think I resolved the problem, but it is strange.
  5. This linker error is given where a stack alignment conflict is detected in object code.
  6. Get 1:1 Help Now Advertise Here Enjoyed your answer?
  7. The image entry point must correspond to a valid instruction in a root-region of the image.L6204E Entry point (
    ) does not point to an instruction.

An file I/O error occurred while reading, opening, or writing to the specified file.L6004U Incomplete library member list for . Only the first such symbol from the object symbol table is accepted by the linker. By contrast, armcc resolves all such references at compile-time.L6319W Ignoring command. Somebody has referenced a symbol and has either forgotten to define it or has incorrectly defined it.

L6049U The linker is unable to continue the link step (). But both ways I get "Error: 13 The data is invalid." dism.log (1020 KB) 0 Sonora OP JW0914 Sep 16, 2015 at 4:29 UTC Joshua8302 wrote: I am This might be caused by explicitly specifying the (wrong) ARM-supplied library on the linker command-line. An illegal alignment was specified for an ELF object.L6291E Cannot assign Fixed Execution Region Load Address:.

L6229E Scatter description is empty. The fact it's an install.wim should register a red flag, as Windows setup normally uses an install.esd.   The tool does download an install.esd, but you need to grab it from So lange muss man sich im Zweifel eben einloggen 🙂 Grüße, Alexander Volz Zeige alle 2 Kommentare Kategorien Allgemein Deployment Hardware MDT SCCM Scripting / Paketierung Treiber Web Entwicklung Windows 10 This error might be because a load region LR2 with a relative base address immediately follows a ZI execution region in a load region LR1.

permalinkembedsaveparentgive gold[–]centerofuniverse[S,🍰] 0 points1 point2 points 2 years ago(1 child)That worked. For example: ER_foo 0 ImageBase(ER_foo) L6385W Addition overflow on line L6386E Exec Region Expressions can only be used in base address calculations on line L6387E Load Region Expressions can L6435W Ignoring incompatible wchar_t size attribute on Section (
). This typically happens when one uses +FIRST or +LAST, for example in a scatter file, attempting to force RW before RO.L6220E region size ( bytes) exceeds limit ( bytes).

Thanks "Humphrey" wrote: > On Mar 21, 7:46 am, tedkar wrote: > > I recently upated a RIS install to WDS successfully. his comment is here If your post requires a picture put it in the text. /r/iiiiiiitttttttttttt (i7t12) for your rage comics, and "Read Only Friday" posts. /r/techsupportanimals for your memegenerator images Link Flair Filters Gilded This reproduces the warning: AREA Block, CODE, READONLY EXPORT func1 ;IMPORT || Lib$$Request$$armlib|| IMPORT printf func1 LDR r0,=string BL printf BX lr AREA BlockData, DATA string DCB "mystring" END The linker Need some easy way to do a ..

For more details on why you might see this error and possible solutions, see the description for error L6815U.L6001U Could not read from file . I was able to import the BOOT.WIM file of the DVD. > I have about 6.5 GB free on the drive, the user account is a domain admin > (its a This can occur accidentally when using wildcards (*). this contact form Sponsored Links 28-11-2007, 12:02 PM #2 Humphrey Guest Posts: n/a Re: WDS adding INSTALL.WIM Vista DVD On Mar 21, 7:46 am, tedkar wrote: > I recently upated

Es ergab sich auch hier das gleiche Fehlerbild. I also installed manually a system with this disk without a problem. L6248E () in region '' cannot have relocation to in region ''.

The problem was a defective CD-ROM drive in the fysical server which damaged the DVD Disk. 0 LVL 1 Overall: Level 1 Message Author Closing Comment by:Hoenderdos ID: 397184582013-12-14 The

Is so, please try a Windows Vista 64bit retail DVD (including a install.wim for other versions of Windows Vista) to check the result.   You can also uninstall and reinstall WDS Look for a directory named Panther, it will contain the logs, which should have better information than the simple error message. permalinkembedsaveparentgive gold[–]NeedKarmaForFoodWin Admin 0 points1 point2 points 2 years ago(0 children)You're welcome :) permalinkembedsaveparentgive gold[–]observantguyNetwork/Security Operations / AD Admin / Peering Coordinator 0 points1 point2 points 2 years ago(0 children)If the error occurs at some L6652E Cannot reverse Byte Order of Data Sections, input objects are requested data byte order is .

Organize IT infrastructure Organize and document all assets of the IT department Change Management solution in SharePoint Implement a new Change Management solution in SharePoint Online using InfoPath 2013 and L6418W Tagging symbol defined in () is not recognized. The specified library member is either corrupt, or is in a file format that the linker cannot recognize.L6009U File : Endianness mismatch. navigate here Originally I had downloaded the SA Enterprise version from the MLVS site and was using this.

This might indicate a compiler fault. See the following in the Linker Reference:--first=section_id--last=section_id.L6216E Cannot use base/limit symbols for non-contiguous section The exception-handling index tables generated by the compiler are given the section name .ARM.exidx. This means that an unused section has had its base and limit symbols referenced. This permits efficient use of LDRD and STRD instructions (in ARM Architecture 5TE and later) to access eight-byte aligned double and long long data types.Symbols such as ~PRES8 and REQ8 are

require four-byte alignment of eight-byte datatypes clashes with require eight-byte alignment of eight-byte data types. L6452E (
) built permitting Thumb is forbidden in an ARM-only link. However, Windows Vista 64bit install images cannot be added. The problem was a defective Go to Solution 3 2 Participants Hoenderdos(3 comments) LVL 1 ozzeczek LVL 8 Windows Server 20085 MS Legacy OS3 MS Server OS1 4 Comments LVL

TechNet Products IT Resources Downloads Training Support Products Windows Windows Server System Center Browser   Office Office 365 Exchange Server   SQL Server SharePoint Products Skype for Business See all products To resolve this, remove the +ZI attribute from the foo.o line in your scatter file.L6315W Ignoring multiple Build Attribute symbols in Object . There can be only one SHLNAME entry in an edit file. Internal consistency check failed L6744E Relocation #: () with respect to undefined symbol .

All rights reserved. Library selection may be impaired. L6419W Undefined symbol (referred from ) imported. FIXED means make the load address the same as the execution address.

L6245E Failed to create requested ZI section ''. L6733W () contains offset relocation from to , load regions must be rigidly relative.